Liquid Level Switch LLS14

Float-type level switch

  • Operating Principle

A float guided on a non-magnetic tube follows the level of the liquid surface, thereby actuating some reed contacts, monostable or bistable, inside the tube via a built-in magnet system .

  • Application Range

LLS14 is ideal wherever liquid levels have to be checked in process and storage tanks .

  • Typical Liquids are :

    • Water and aqueous fluids

    • Acids/alkalis

    • Organic and inorganic solvent

All wetted parts can be coated with plastic for use in aggressive media .

  • Interface Level Switching

If two liquids with different densities are stored in one tank, the level of the interface can be switched using a special interface-type float . The weight and buoyancy of the float are such that it floats on the heavier and sinks in the lighter liquid . The minimum difference in density between both liquids should be greater than 100 g/l (6.240lb/ft³), and the float must be fully  immersed in the lighter liquid . If the lighter liquid is not always stored in the tank, this must be specified on ordering to ensure appropriate float design .

Technical data

Instrument Type                                               LL S14                                                

Measuring Conditions                                                                                                   

Product                                                            Liquid                                                  

Temperature                                                   -40...+130˚C(-40...+266˚F)

Density                                                           ³0.4kg/l (25lb/ft³)

viscosity                                                         £5000mpa.s

Operating Pressure                                            30 bar (435 psig)                                

Ambient Temperature                                      -40...+60˚C (-40...+140˚F)

Overall Length                                                 0.2...6m (0.6...20ft)

Switching accuracy                                          ±3mm (±0.12")

Materials                                                                                                                     

Housing                                                         Stainless steel 316L, 304L, Aluminum, P.P.

Guide tube                                                     Stainless steel 316L, 304L, P.P.

Float                                                             Stainless steel 316L, 304L, P.P.

Connection                                                                                                                  

Screw connection                                           G 1/2", 1/2" NPT, G 1 1/2",1 1/2" NPT

                                                                    , G 2",2" NPT

Flange                                                           All standard and size

Protection category                                         IP 66

Operating voltage                                           30 V

Max. Current switched                                      80mA                                                   

Max. Contact Rating                                         2.4 W(VA)                                             

 

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:28 |

Liquid Level Transmitter LLT14 float level meter with electric transmitter

  • Operating principle

The device operates on the float principle . A float guided on a non-magnetic tube follows the level of the liquid surface, thereby actuating the reed switches located inside the tube by means of a built-in magnet system . The reed switches shunt over parts of a resistor string . The magnet system operates the read switches according to the position of the float and thus causes the resistance of the resistor string to change as a function of the liquid level . The float travel distance can be limited by stops fitted to the guide tube . The signal conditioner produces an output signal from 4...20mA .

  • Application Range

the LLT14 is designed for liquid level measurement in stock or process tank .

The products must not be adhesive or of high viscosity . The min. Density is 0.4kg /l or 25lb/ft³ .

Optional : interface level between two immiscible liquids . The difference in density between both liquids has to be min. 100g/l .

  • Typical liquids are :

    • water and aqueous fluids

    • Acids/Alkalis

    • Organic and inorganic solvents

All wetted parts can be coated with plastic for use in aggressive media .

Technical data

Instrument Type                                              LLT14                                                    

Measuring Conditions                                                                                                    

Product                                                          Liquid                                                     

Temperature                                                 -40...+130˚C(-40...+266˚F)

Density                                                          ³0.4 kg/l (25lb/ft³)

viscosity                                                        £5000 mPa.s

Operating Pressure                                         10 bar (145 psig)                                     

Ambient Temperature                                    -40...+60˚C (-40...+140˚F)

Overall Length                                                 0.2...6m (0.6...20ft)

Measuring accuracy                                         ±10mm (+0.4")

Materials                                                                                                                     

Housing                                                          Stainless steel 3161, 304L, Aluminium, P.P.

Guide tube                                                      Stainless steel 316L, 304L, P.P.

Float                                                              Stainless steel 316L, 304L, P.P.

Connection                                                                                                                   

Screw connection                                            G 1/2", 1/2" NPT, G 2", 2" NTP

Flange                                                            All standard and size

Protection category                                          IP 66

Current output                                                4...20mA , HART , Profibus ,

                                                                     Fundation Fieldbus

Power supply                                                  15...24VDC                                            

Max. Load                                                       400 W                                                   

 

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:26 |

LONG DISTANCE DATA TRANSMISSION SYSTEM

In addition to the local indicator , the LLI73 can be equipped with an electrical long-distance data transmission system . this equipment consists of a tube that is clamped onto the measuring tube . The tube is fitted with reed contacts and a chain of resistors . The magnet in the float of the LLI73 actuates different reed contacts according to the liquid level and thus changes the total resistance of the resistor chain as a function of the liquid level . The resistance is converted from ohms to a current of 4 to 20mA , profibus , Hart or foundation fieldbus outputs by the signal converter built into the connection housing . the LLI73 can be operated in series with the load as 2-wier signal converters direct with 16 to 28 VDC .With a digital indicator the liquid level can be displayed on a 4 character LED display .

Tecnical data                                                                                                        

Overall length                                                                                                          

Standard                                       £400cm(£13ft)

Option                                           £600cm(£20ft)

Resolution                                                                                                              

Standard                                        10mm(0.39in)

Option                                            7mm(0.28in)

                                                     5mm(0.20in)

Measuring error                                                                                                     

Standard                                        ±10mm(±0.39in)

Option                                            ±7mm(±0.28in)

                                                     ±5mm(±0.20in)

Ambient temperature                      -20...+70˚C (-4...+158˚F)                                     

Process temperature                       -20...+200˚C(-4...+390˚F)                                    

Materials                                                                                                                

Housing                                         Stainless steel 316L , 304L , Aluminium , P.P.

Tube                                             Stainless steel 316L , 304L , P.P.

Protection category                         IP66                                                                 

Output                                                                                                                   

                                                     4...20mA

                                                     Profibus                                                               

                                                     HART

                                                     Foundation fieldbus

Power supply                                 16...28 v DC                                                       

Max . Load                                     20mA , Max. 500                                           

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:24 |

MAGNETICALLY COUPLED LEVEL SWITCHES

In order to signal specific liquid levels, the LLI73 can be equipped with various types of limit switch that are clamped to the measuring tube and are thus adjustable over the whole measuring range . They are actuated by the magnet system in the float . Depending on operating condition, various limit switches are available

 

 


ادامه مطلب
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:21 |

TYPE LLI73PP                                                                        

All weted part stainless steel coated with  poly pro pilen  

 

  • Max. Temperature 100˚C
  • Max. Pressure 6bar
  • Min. Density 0.5Kg/lit
  • Usable in corrosive service
  • Out put

    • 4...20mA

    • Hart

    • Profibus

    • Foundation

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:18 |

TYPE LL73 SP                                                    

All weted part made of poly pro pilen             

  • Max. Temperature  150˚C
  • Max. Pressure 40 bar
  • Min. Density  0.6 Kg/lit
  • Usable in corrosive service
  • Out put

    • 4...20mA

    • Hart

    • Profibus

    • Foundation field bus

 

 

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:15 |

TYPE LLI73SS                                                     

 

All weted part made of stainless steel             

  • Max. Temperature 400˚C

  • Max. pressure 80bar

  • Min. Density 0.5Kg/lit

  • Magnetic Limit switch

  • Out put

    • 4...20mA

    • Hart

    • Profibus

    • Foundation field bus

 

 

 

 

     

 
 
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:12 |

Mounting types

Side mounting

For mounting LLI73 to the side of the tank, any of the four type of process connection is available :

 


ادامه مطلب
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 18:8 |

DESCRIPTION

The LLI73 liquid-level indicator is used for measuring liquid levels in open or pressurized tanks . Due to its special design , the unit is particularly suitable for use in connection with aggressive , noxious or flammable substances and tough service condition .

OPERATING PRINCIPLE

The unit operates on the principle of communicating tubes . The measuring tube is connected as a side vessel to the tank such that the same conditions are obtained in the tubs as those in the tank .The float is equipped with a system of permanent magnets to transmit measured values to the local indicator . The magnet system of the float activates the magnetic flaps according to the liquid level . The column of the reversed yellow magnetic flaps is the indication of the liquid level


ادامه مطلب
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 17:53 |

After sale services

  • Guarantee for LLI73

electrical devices : 18 months

non electrical devices : 24 months

  • Guarantee for LLS14 & LLT14

18 months

Besides after ending these times still we will support our costumers up to 10 years .

 

 
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 17:46 |
 

                                                

 

Products                                                

          

  • LLI73 SS
  • LLI73 SP
  • LLI73 PP
  • LLT14
  • LLS14

TYPICAL APPLICATION

  • Oil
  • Water
  • Oil and water interface
  • Acids - Hydrofluoric
  • Hydrocholoric , Nitric , Solforic
  • etc
  • Refined petrochemical - Gasoline , Propane , Batane , Ethylenc . etc
  • Solvent - Acetone , tolaene
  • Gas condensate
  • Heat transfer fluids downtherm , terminal , glycol
  • Alcohols
  • Caustics
  • Chlorine
  • Steam condensate - Boiler feedwater heater boilerydrum level control
  • Ammonia
  • Liquid sulphur
  • Most liquid to liquid interfaces

TYPICAL INDUSTRIES

  • Oil production and refining facilities
  • petrochemical plants
  • Chemical plants
  • Gas plants
  • Power plants
  • Water and wast water treatment
  • Food and beverage
  • Pharmaceutical
  • Pulp and Paper
  • Biotech
  • Semi conductor
+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 17:43 |
Tehran Delik Engineering Co." Has established for designing, manufacturing and producing measuring instruments specially liquid-level indicators and liquid level controls . Scientific and engineering experts in different areas of the company's fields are active here . Currently, the company is engaged in manufacturing magnetic level gauges , magnetic level switches , magnetic level transmitter , conductive level switches

These products are applicable for different industrial sectors, while being practically used .Numerous industrial apply the company's productions and after-sale services

+ نوشته شده توسط حسن عبدالهیان در پنجشنبه چهاردهم تیر 1386 و ساعت 17:28 |

img/daneshnameh_up/7/7f/pala.jpg
      

موارد استعمال برخی از برش های نفتی بدست آمده از نفت خام

شیرین کردن آب دریا

یکی از موارد استعمال گازهای نفتی در صنایع وابسته به پالایشگاهها تهیه آب شیرین از آب شور می‌باشد.

به عنوان سوخت

از جمله ، بنزین برای سوخت موتورهای مختلف ، کروزون سوخت اغلب تراکتورها و ماشین‌های مورد استفاده در کشاورزی و همچنین موتورهای جت هواپیماها اغلب از کروزون یا نفت سفید می‌باشد، گازوئیل که موتورهای دیزل بعنوان سوخت از نفت گاز (گازوئیل) استفاده می‌نمایند، نفت کوره یا مازوت یک جسم قابل احتراق با قدرت حرارتی 10500 کالری بوده که بخوبی می‌تواند جانشین زغال سنگ گردد و سوختن آن تقریبا بدون دود انجام می‌گیرد.

روشنایی

از کروزون جهت روشنایی و همچنین برای علامت دادن به کمک آتش استفاده می‌شود، چون نقطه اشتعال کروزون بالاتر از 35 درجه است، لذا از نظر آتش‌سوزی خطری ندارد.

حلال

از هیدروکربورهای C4 تا C10 می‌توان برش‌هائی با دانسیته و نقاط جوش ابتدائی و انتهایی متفاوت تهیه نمود که مورد استعمال آنها اغلب بعنوان حلال می‌باشد. بعنوان مثال ، اتر نفت یک حلال سبک با نقطه جوش 75-30 درجه سانتیگراد و وایت اسپیریت (حلال سنگین) که از تقطیر بنزین بدست می‌آید بعنوان حلال ، رنگ‌های نقاشی و ورنی ها استفاده می‌گردد. همچنین برای تمیز کردن الیاف گیاهی و حیوانی و یا سطح فلزات از برش‌های خیلی فرار (تقطیر شده قبل از 110 درجه سانتیگراد) استفاده می‌شود.

روان کاری

  • روغنهای چرب کننده: نوعی روغن که جهت روان کاری بکار می‌رود. بستگی به شارژ ، سرعت ، درجه حرارت دستگاه دارد. انواع روغنها عبارتند از:

  1. روغن دوک برای چرب کردن دوک ، موتورهای الکتریکی کوچک و ماشین های نساجی و سانتریفوژهای کوچک
  2. روغن ماشین‌های یخ سازی جهت روغنکاری کمپرسورهای آمونیاکی کارخانجات یخ‌سازی
  3. روغن ماشین‌های سبک جهت روان کاری موتورهای الکتریکی ، دینام‌ها و سانتریفوژهای با قدرت متوسط
  4. روغن ماشین‌های سنگین مخصوص روغنکاری موتورهای دیزلی است مانند دیزل‌های سورشارژه و غیره
  5. روغن برای سیلندرهای ماشین بخار
  6. روغن برای توربین ها
  7. روغن برای موتورهای انفجاری (اتومبیل و غیره)
  8. روغن دنده
  9. روغن موتورهایی که دائما با آب در تماس است.

  • گریس ها: یک روان کننده نیمه جامد است و متشکل از یک روغن نفتی و یک پر کننده (از سری صابونهای فلزی) یا سفت‌کننده (از مواد پلیمری) می‌باشد. کاربرد گریس بیشتر برای اتومبیل‌ها و برخی صنایع مناسب می‌باشد.

  • آسفالت و قیراندودی: در حال حاضر 75 درصد از باقیمانده حاصل از عمل تقطیر در خلاء برای پوشش جاده‌ها مورد استفاده قرار می‌گیرد.

  • موارد استعمال داروئی: از قبیل وازلین باعث نرم شدن پوست بدن گردیده و برای بهبود سرمازدگی نیز موثر است.

  • پارافین: از پارافین ذوب شده و خالص شده جهت ساخت داروهای زیبائی استفاده می‌گردد.

  • گلیسیرین: مقدار قابل ملاحظه ای از این ماده ، از نفت تهیه می‌گردد. علاوه بر مصارفی که گلیسیرین در صنعت (برای تهیه باروت دینامیت ، مرکب و غیره) دارد، از آن برای فرم نگه داشتن پوست بدن و یا تهیه داروهائی از قبیل گلیسیرین یده استفاده می‌شود.
+ نوشته شده توسط حسن عبدالهیان در دوشنبه چهارم تیر 1386 و ساعت 19:44 |

گرانی

چگالی نفتهای خام را بیشتر بر حسب درجه A.P.I به جای گرانی ویژه (چگالی نسبی) بیان می‌کنند. ارتباط بین این دو ، به گونه ای است که افزایش گرانی API با کاهش گرانی ویژه مطابقت می‌کند. گرانی نفت خام می‌تواند بین پایینتر از 10API تا بالاتر از 50API قرار بگیرد، ولی گرانی اکثر نفتهای خام در گستره بین 20 تا 45API قرار دارد. گرانی API همواره به نمونه مایع در 60 درجه فارینهایت اشاره دارد.

مقدار گوگرد

مقدار گوگرد و گرانی API دو خاصیتی هستند که بیشترین اثر را به ارزش‌گذاری نفت خام دارند. مقدار گوگرد بر حسب درصد وزنی گوگرد بیان می‌شود و بین 0,1 در صد تا 5 درصد تغییر می‌کند. نفتهایی که بیش از 0,5 درصد گوگرد دارند، در مقایسه با نفتهای کم‌گوگردتر ، معمولا محتاج فراورشهای گسترده‌تری هستند.

نقطه ریزش

نقطه ریزش نفت خام بر حسب F˚ یا c˚ معرف تقریبی پارافینی‌ بودن یا آروماتیکی ‌بودن نسبی آن است. هرچه نقطه ریزش پایینتر باشد، مقدار پارافین کمتر و مقدار آروماتیک بیشتر است.

حلالیت

قابلیت انحلال هیدروکربورها در آب عموما خیلی کم می‌باشد. مقدار آب موجود در هیدروکربورها با افزایش درجه حرارت زیاد می‌شود. حلالیت هیدروکربورها در کلروفرم ، سولفورکربن و تتراکلریدکربن حائز اهمیت است که با افزایش درجه حرارت ، زیاد و با افزایش وزن مولکولی کاسته می‌گردد. قابلیت انحلال آروماتیکها بیشتر بوده و بعد از آنها اولفین‌ها - نفتن‌ها - متانی‌ها قرار دارد.

ضمنا قابلیت انحلال ترکیبات اکسیژنه - ازته - سولفوره ، کمتر از هیدروکربورها می‌باشد. بالاخره نفت ، حلال هیدروکربورهای گازی‌شکل و تقریبا تمام هیدرورکربورهای جامد - گریس‌ها - رزین‌ها - گوگرد و ید می‌باشد
.

نقطه جوش

نقطه جوش هیدروکربورهای خالص با وزن مولکولی و همچنین برای سری‌های مختلف با تعداد مساوی اتم کربن بترتیب از هیدروکربورهای اشباع‌شده به اولفین‌ها - نفتن‌ها و آروماتیکها افزایش می‌یابد. بدین ترتیب نقطه جوش هیدروکربورهای اشباع شده و اولفین‌ها از همه کمتر و سیکلوآلکان‌ها و آروماتیکها از سایرین بیشتر می‌باشد.

برای برش‌های نفتی که مخلوطی از هیدروکربورهای مختلف می‌باشند، یک نقطه جوش ابتدائی و یک نقطه جوش انتهایی در نظر گرفته می‌شود و حد فاصل بین این دو نقطه برای یک برش به نوع مواد سازنده اغلب زیاد و متغیر می‌باشد که به این حد فاصل بین دو نقطه "گستره تقطیر" گفته می‌شود
.

گرمای نهان تبخیر

گرمای نهان تبخیر در یک سری همولوگ از هیدروکربن‌ها بترتیب از مواد سبک به سنگین کاهش می‌یابد و همچنین مقدار آن از یک سری به سری دیگر ، مثلا بترتیب از آروماتیکها به نفتن‌ها و هیدروکربورهای اشباع شده نقصان می‌یابد. بنابراین گرمای نهان تبخیر با دانسیته فراکسیون مربوط بستگی دارد.

قدرت حرارتی

قدرت حرارتی عبارت از مقدار کالری است که از سوختن یک گرم ماده حاصل می‌شود. قدرت حرارتی هیدروکربورها به ساختمان مولکولی آنها و قدرت حرارتی یک برش نفتی به نوع و مواد سازنده آن سبتگی دارد. قدرت حرارتی متان بیشتر از سایر هیدروکربورها و برابر با 13310 کیلوکالری به ازای یک کیلوگرم می‌باشد و مواد سنگین حاصله از نفت خام دارای قدرت حرارتی در حدود 10000 کیلو کالری می‌باشد.
+ نوشته شده توسط حسن عبدالهیان در دوشنبه چهارم تیر 1386 و ساعت 19:41 |

نفت خام

امروزه چاههای نفت متعددی در سراسر جهان وجود دارد که از آنها نفت استخراج می‌کنند و به نفتی که از چاه بیرون کشیده می‌شود، نفت خام می‌گویند. نفت خام را تصفیه می‌کنند، یعنی هیدروکربنهای گوناگونی را که نفت خام از آنها تشکیل شده است از یکدیگر جدا می‌کنند که به این کار پالایش نفت می‌گویند و در پالایشگاهها این کار انجام می‌شود. نفت منبع انرژی و سرچشمه مواد اولیه بسیاری از ترکیبات شیمیایی است و این دور از عوامل اصلی اقتصادی مدرن بشمار می‌رود. در صنایع جدید از ثروت بیکران و تغییر و تبدیل مواد خام اولیه آن بی‌اندازه استفاده می‌شود.

تشکیل نفت

نحوه پیدایش نفت دقیقا تشخیص داده نشده و در این مورد فرضیات گوناگونی پیشنهاد شده است. برخی از این تئوریها ، مربوط به مواد معدنی و بعضی دیگر مربوط به ترکیبات آلی می‌باشد.

تشکیل نفت از مواد معدنی

اساس این فرضیه بر این است که کربورهای فلزی تشکیل شده در اعماق زمین در اثر تماس با آب‌هایی که در زمین نفوذ می‌نماید، ابتدا ایجاد هیدروکربورهای استیلنی با رشته زنجیر کوتاه می‌کند. سپس هیدروکربورهای حاصل در اثر تراکم و پلیمریزه شدن ایجاد ترکیبات پیچیده و کمپلکس را می نماید که اغلب آنها اشباع شده است.

تشکیل نفت از مواد آلی

بر اساس این فرضیه تشکیل نفت را در اثر تجزیه بدن حیوانات در مجاورت آب و دور از هوا می‌دانند. زیرا در این شرایط ، قسمت اعظم مواد ازته و گوگردی تخریب و مواد چرب باقیمانده در اثر آب ، هیدرولیز می‌گردد. اسیدهای چرب حاصله ، تحت اثر فشار و درجه حرارت با از دست دادن عوامل اسیدی تولید هیدروکربورهائی با یک اتم کربن کمتر می‌نماید.

"انگلر Engler" از تقطیر حیوانات دریائی توانسته است مواد نفتی را تهیه نماید و با توجه به خاصیت "چرخش نوری" مواد نفتی که علت آن وجود گلسترین است (ماده ای که در بدن حیوانات وجود دارد) این فرضیه بیان و مورد تایید شده است. در صورتی که فرضیه های دیگر که مبتنی بر اساس مواد معدنی در تشکیل نفت می‌باشد، هیچگونه توضیح و دلیل قانع کننده ای در مورد این ویژگی نمی‌تواند بیان نماید.

همچنین نفت می‌تواند از تجزیه گیاهان تولید گردد. در این حالت ، خاصیت چرخش نور را به علت وجود ترکیب مشابه گلسترین یعنی پلی استرولها می‌دانند."مرازک Mrazec" ،
میکروبها را در این تغییر و تبدیل موثر می‌داند.

تئوری تشکیل نفت بر مبنای مواد آلی ، فعلا بیشتر مورد قبول می‌باشد و اختلاف قابل ملاحظه‌ای را که بین ژیزمان‌ها (منابع نفتی) مشاهده می‌گردد، بعلت شرایط و عوامل مختلف تشیکل ژیزمان‌ها می‌دانند
+ نوشته شده توسط حسن عبدالهیان در دوشنبه چهارم تیر 1386 و ساعت 19:30 |



نفت ، "پترول" ، یا به اصطلاح روغنهای معدنی مخلوطی از هیدروکربورها می‌باشد که منابع آن اغلب در اعماق زمین وجود دارد. انگلیسیها کلمه لاتین "پترولئوم Petroleom " را پذیرفته‌اند، درصورتیکه آلمانیها آن را " اردل Erdol " به معنای روغن زمینی می‌نامند.


img/daneshnameh_up/0/01/098148.jpg

تاریخچه

این ماده را از قرنها پیش بصورت گاز در آتشکده و یا به فرم قیر (کاده ای که پس از تبخیر مواد فرار یا سبک نفت از آن باقی می‌ماند) می‌شناخته‌اند یا بطوری که در کتب مقدس و تاریخی اشاره شده است که در ساختمان برج بابل از قیر استفاده گردیده و کشتی نوح و گهواره موسی نیز به قیر اندوده بوده است. بابلی‌ها از قیر بعنوان ماده قابل احتراق در چراغها و تهیه ساروج جهت غیر قابل نفوذ نمودن سدها و بالاخره جهت استحکام جاده‌ها استفاده می‌کرده‌اند.

مدت زمان مدیدی ، مورد استعمال نفت فقط برای مصارف خانگی و یا به عنوان چرب‌کننده‌ها بود، اما از آغاز قرن شانزدهم میلادی روز به روز موارد استعمال آن رو به افزایش نهاد تا اینکه در سال 1854 دو نفر داروساز وجود یک فراکسیون سبک قابل اشتعال را در
روغن زمینی تشخیص دادند و همچنین به کمک تقطیر ، مواد دیگری بدست آوردند که برای ایجاد روشنایی بکار می‌رفت. بر اساس این کار آزمایشگاهی بود که بعدا دستگاههای عظیم تصفیه نفت طرح‌ریزی و مورد بهره برداری قرار گرفت. صنعت نفت در آتازونی در سال 1859 شروع شد.

تاریخچه استخراج نفت در ایران

صنعت نفت ایران نیز از سال 1908 پس از هفت سال تفحص مکتشفین و کشف نفت در مسجدسلیمان واقع در دامنه جبال زاگرس ، پا به عرصه وجود گذاشت.
+ نوشته شده توسط حسن عبدالهیان در دوشنبه چهارم تیر 1386 و ساعت 19:24 |


Powered By
BLOGFA.COM



www.azadhacker.blogfa.com